Glossary#
- Assay constant#
A quantity set by the experimental design rather than fitted, such as total receptor (
RT), total tracer (LsT) or the tracer’s dissociation constant (Kds). Binding models require their assay constants infit(..., fixed={...}).- Biological replicate#
- Bound fraction#
The fraction of tracer that is bound to receptor, \(F_b^*\). The equilibrium models compute it and map it linearly to the response.
- Competitive binding#
An assay in which unlabeled competitor is titrated into a fixed mixture of receptor and tracer. The competitor’s affinity is inferred from how much tracer it displaces.
- Competitor#
The unlabeled ligand in a competitive-binding assay, usually the compound being characterized.
- Concentration-like parameter#
A parameter with concentration units, such as
IC50,KdorRT.bindcurvefits these on a \(\log_{10}\) scale and averages them across independent experiments as geometric means.- Depletion#
A significant part of a species being consumed by binding, so that its free concentration differs noticeably from its total concentration. Models that account for depletion use total concentrations and solve the mass balances.
- Direct binding#
An assay in which receptor is titrated into a fixed concentration of tracer, to measure the tracer’s own dissociation constant.
- Dissociation constant#
\(K_d = [R][L]/[RL]\) at equilibrium. It equals the free-ligand concentration at which half of the receptor sites are occupied. A lower \(K_d\) means tighter binding. In
bindcurve,Kdsis the tracer’s constant andKdthe competitor’s.- Fixed parameter#
A parameter held at a given value during fitting instead of being estimated. Set with
fit(..., fixed={...}).- Geometric mean#
The mean of the logarithms, transformed back: \(10^{\overline{\log_{10} x}}\). Used for concentration-like parameters such as IC₅₀ and \(K_d\), whose values from independent experiments are approximately log-normally distributed.
- Hill slope#
The steepness parameter \(h\) of the logistic model. \(h = 1\) is the steepness expected for simple one-site binding; larger values give steeper curves.
- IC₅₀#
The concentration of an inhibitor or competitor that brings the response halfway between the two plateaus. It depends on the assay conditions and is not in general a dissociation constant.
- Independent experiment#
A complete repeat of a dose-response experiment, prepared and measured separately, for example on a different day with a fresh dilution series or protein preparation. Also called a biological or experimental replicate. Independent experiments capture the variation between repeats of the whole experiment, which is usually much larger than the scatter between technical replicates. They are identified by the
experiment_idcolumn, fitted separately, and form the \(n\) of the summary statistics.- Logistic model#
The empirical four-parameter dose-response curve (
ic50model), with two plateaus, a midpoint and a Hill slope.- Nonspecific binding#
Binding of a ligand to something other than the receptor site, such as the plate or other proteins. The
_totalmodels treat it as proportional to the free ligand concentration, with factorNs(tracer) orN(competitor).- pIC₅₀#
\(-\log_{10}(\mathrm{IC}_{50})\) with the IC₅₀ expressed in mol/L. An IC₅₀ of 1 µM corresponds to a pIC₅₀ of 6.
- Plateau#
The response that a curve approaches at zero or at very high concentration. Every model has the two plateau parameters
yminandymax.- Receptor#
The binding partner whose sites tracer and competitor occupy, for example a protein. Its total concentration is
RT.- Replicate mean#
The average of the technical replicates at one concentration within one independent experiment. Fits use replicate means, not single wells.
- Residual#
The difference between a measured replicate mean and the fitted curve at the same concentration.
- Technical replicate#
A repeated measurement of the same sample within one independent experiment, such as duplicate or triplicate wells on one plate. Technical replicates reflect the precision of the measurement itself (pipetting, instrument noise), not the variation between experiments. Rows with the same compound, experiment and concentration are technical replicates; they are averaged before fitting and do not count towards \(n\).
- Ternary complex#
A receptor bound to tracer and competitor at the same time (\(RLL^*\)), allowed only in the four-state models.
- Tracer#
A labeled ligand whose binding produces the measured signal, for example a fluorescent probe. Its total concentration is
LsT.