Checking fits#

Check every fit before using its parameters. A fit can converge and still describe the data poorly, or return a parameter the data do not determine.

The examples on this page use the IC₅₀ tutorial dataset: two inhibitors, three independent experiments each, with technical triplicates.

import matplotlib.pyplot as plt

import bindcurve as bc

data = bc.DoseResponseData.from_csv("../tutorials/data/ic50.csv", format="wide")
results = bc.fit(data, "ic50")

The experiment table#

results.experiments() has one row per fit, that is, per independent experiment of each compound:

results.experiments()
compound_id experiment_id success message warnings n_data rss r_squared ymin ymin_stderr ymax ymax_stderr IC50 IC50_stderr hill_slope hill_slope_stderr
0 inhibitor_a exp_1 True `ftol` termination condition is satisfied. None 11 1.836502 0.999878 4.521992 0.309105 94.671635 0.384181 67.754019 1.343892 1.046084 0.019801
1 inhibitor_a exp_2 True `ftol` termination condition is satisfied. None 11 16.761434 0.999023 2.921499 1.001466 100.672909 1.213162 75.135651 4.481710 0.963821 0.051435
2 inhibitor_a exp_3 True `ftol` termination condition is satisfied. None 11 12.324292 0.999355 1.777391 0.921444 103.382595 0.892147 134.704492 6.285989 1.008740 0.043799
3 inhibitor_b exp_1 True `ftol` termination condition is satisfied. None 11 27.737383 0.998019 5.338058 2.016768 97.445304 0.873941 1434.410084 96.319489 1.389277 0.111311
4 inhibitor_b exp_2 True `ftol` termination condition is satisfied. None 11 4.190714 0.999758 8.480239 0.623360 104.984125 0.342225 944.570218 19.862690 1.566379 0.045515
5 inhibitor_b exp_3 True `ftol` termination condition is satisfied. None 11 10.039911 0.999367 4.104765 1.268512 103.450061 0.523559 1570.257777 60.500640 1.372416 0.061722

Column

Meaning

success

Whether the optimizer converged

message

Optimizer or error message

warnings

Quality warnings for converged fits, described below

n_data

Number of concentrations fitted

rss

Residual sum of squares of the replicate means

r_squared

Coefficient of determination of the replicate means

parameter

Fitted value of each free parameter

parameter_stderr

Its standard error within this experiment

\(R^2\) is close to 1 for almost any sigmoidal data set and says little about whether the model is appropriate. Use it together with the plots below, not on its own.

Quality warnings#

bindcurve flags converged fits whose estimates may not be supported by the data. fit then emits a UserWarning with the number of flagged fits, the warnings column gives the reasons, and the N_flagged column of results.summary() counts them per compound.

Warning

Meaning

What to do

name lies outside the tested concentration range.

The IC₅₀ or \(K_d\) was extrapolated beyond the highest or lowest concentration.

Extend the concentration range. Otherwise report the value only as above or below the tested range.

name is poorly determined: its standard error exceeds the estimate.

The data constrain the parameter only weakly, typically because a plateau or the midpoint is not well covered.

Add concentrations around the midpoint and on both plateaus, or fix a parameter whose value is independently known.

Standard errors could not be estimated.

Some parameters cannot be separated from each other with these data, for example flat data or too few concentrations.

Check the data and the concentration range, and consider fixing a parameter whose value is known.

Flagged fits are still included in the summary statistics. To leave one out, remove its rows from the data and fit again:

table = data.table
keep = ~((table["compound_id"] == "inhibitor_b") & (table["experiment_id"] == "exp_2"))
results = bc.fit(bc.DoseResponseData(table[keep]), "ic50")

Plots#

Plot each fit over its data. The replicate means should lie on the curve, with both plateaus and the midpoint covered by measured concentrations:

fig, ax = plt.subplots(figsize=(5, 3.5))
bc.plot_fits(results, compounds="inhibitor_a", ax=ax)
ax.set_xlabel("inhibitor (nM)")
ax.set_ylabel("activity (% of control)")
ax.legend()
plt.show()
../_images/6109acd217829e7b2ac9e55cac5ee3f8812a4416008336faec3e01137c3dde31.png

Residuals show systematic deviations more clearly. For a good fit they scatter randomly around zero. A trend, such as residuals that are positive at both ends and negative in the middle, means that the model does not describe the shape of the curve:

fig, ax = plt.subplots(figsize=(5, 2.5))
bc.plot_residuals(results, compounds="inhibitor_a", ax=ax)
ax.set_xlabel("inhibitor (nM)")
ax.set_ylabel("residual (%)")
ax.legend()
plt.show()
../_images/a643124a339032ef517f4caecb562a99cb0c3a8cbb17323d037ad49033546305.png

Common problems#

  • No lower or upper plateau. The concentration range does not cover the whole curve. The IC₅₀ is then poorly determined; extend the range, or fix the missing plateau if its value is known independently.

  • Hill slope far from 1. Very steep or shallow curves can come from compound aggregation, solubility limits, depletion or more complex binding. Check the data before interpreting the IC₅₀.

  • Systematic residuals. The model does not match the data, for example a three-state model applied to incomplete displacement. Consider a different model.

  • Large differences between independent experiments. Compare the experiment-level values in results.experiments(). An outlying experiment can have a technical cause, such as a pipetting or dilution error.